NetBootLoader VMP1
Page 5 - 30 © 2002 PEP Modular Computers GmbH ID 26037, Rev. 01
SL
FUNCTION: Download Motorola S-Records to data buffer
SYNTAX:
sl [-o[=]<offset>] [-u]
where:
sl command
-o option: offset
<offset> parameter: value: hexadecimal: unsigned
offset to be subtracted from each record's address
-u option: upper
DESCRIPTION: With the command “sl” Motorola S-Records are downloaded to the
data buffer and the record addresses modified accordingly as
required for SDRAM operation (for copying to 0x0).
The “<offset>” parameter may be used to change the record base to
0x0.
The “-u” option selects the SER0 interface as source for the S-Records.
USAGE:
Download S-Records to data buffer and reduce each record’s address by
0x10000.
COMMAND / RESPONSE (none):
sl -o=10000
VER
FUNCTION: Display version number
SYNTAX:
ver
DESCRIPTION: The command “ver” displays the actual version number of the
NetBootLoader.