Processor subsystem System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
42 Intel order number G74211-001 Revision 1.0
6. Processor subsystem
Intel
®
servers report several processor-centric sensors in the SEL.
8.1 Processor Status Sensor
The status sensor reports processor presence or a thermal trip condition. Each processor has a status sensor.
Table 44: Process Status Sensors Typical Characteristics
Byte
Field
Description
11
Sensor Type
07h = Processor
12
Sensor Number
See Table 45
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] 00b = Unspecified Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset as described in Table 45
15
Event Data 2
Not used.
16
Event Data 3
Not used.