Kontron COMe-bHL6 Uživatelský manuál Strana 90

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 129
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 89
COMe-bHL6 / BIOS Operation
Watchdog
Feature Options Description
Auto-reload
Disabled
Enabled
Enable automatic reload of watchdog timers on timeout
Global Lock
Disabled
Enabled
If set to enabled, all Watchdog registers (except
WD_KICK) become read only until the board is reset
Stage 1 Mode
Disabled
Reset
NMI
SCI
Select Action for first Watchdog stage
- Assert WDT Signal
Enabled
Disabled
Enable/Disable assertion of WDT signal to baseboard on
stage timeout
- Stage 1 Timeout 1s
5s
10s
30s
1m
3m
10m
30m
Select Timeout value for first watchdog stage
Stage 2 Mode
Disabled
Reset
NMI
SCI
Select Action for first Watchdog stage
- Assert WDT Signal
Disabled
Enabled
Enable/Disable assertion of WDT signal to baseboard on
stage timeout
- Stage 2 Timeout 1s
5s
10s
30s
1m
3m
10m
30m
Select Timeout value for second watchdog stage
90
Zobrazit stránku 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 ... 128 129

Komentáře k této Příručce

Žádné komentáře