COMe-bPC2 / BIOS Operation
ACPI Cooling Options
Feature Option Description
Passive Trip Point
Disabled
40°C
45°C
50°C
110°C
This value controls the temperature of the ACPI Passive
Trip Point - the point in which the OS will begin
throttling the CPU.
Passive TC1 value
1
2
3
16
This value sets the TC1 value for the ACPI Passive
Cooling Formula. (Only visible when Passive Trip Point is
enabled.)
Passive TC2 value 1
2
5
16
This value sets the TC2 value for the ACPI Passive
Cooling Formula. (Only visible when Passive Trip Point is
enabled.)
Passive TSP value 2
4
10
30
This item sets the TSP value for the ACPI Passive Cooling
Formula. It represents in tenths of a second how often
the OS will read the temperature when Passive Cooling
is Enabled.
Critical Trip Point Disabled
40°C
45°C
50°C
110°C
This value controls the temperature of the ACPI Critical
Trip Point - the point in which the OS will shut off the
system.