Kontron PB-SIO4 Uživatelský manuál Strana 25

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 34
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 24
PB-SIO4 Configuration
ID 19957, Rev. 0300 Page 3 - 3® PEP Modular Computers GmbH
3. Configuration
3.1 PB-SIO4 Address Map and ID Byte
The PB-SIO4 is addressed (odd byte access) by using the carrier board base address
and one of the following offsets for the piggyback location:
Piggyback location A ( the upper position on the carrier board)
Base Address + $01 DUART1
Base Address + $21 DUART2
Base Address + $41 ID Byte
Piggyback location B ( the lower position on the carrier board)
Base Address + $81 DUART1
Base Address + $A1 DUART2
Base Address + $C1 ID Byte
The PB-SIO4 has an ID Byte of $F7 (RS232).
3.2 VMEbus Interrupts
Each DUART device is able to issue an interrupt request (*IRQ) to the carrier board. In
the event of simultaneous interrupt requests those from DUART #1 have priority over
those from DUART #2.
The interrupt level is set by the carrier board. See the carrier board documentation for
setting of the level. The interrupt vector itself is provided by the DUART.
Zobrazit stránku 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 33 34

Komentáře k této Příručce

Žádné komentáře