Kontron RTM8940 Uživatelský manuál Strana 22

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 21
9 RTM8940
www.kontron.com
informed about an RTM insertion is through the RTM Module Hot Swap sensor and a radial presence line on
the RTM connector. All SDRs can be queried using Device SDR commands. Module sensors that have been
implemented are listed below.
2.7.2 Hardware Sensors
Table 2-2:IPMI Hardware Sensors
IPMI
sensor
ID
Sensor Name Description (Sensor Type, Event trigger) Scanning En-
abled under
Power State
Health LED
(Green to Am-
ber)
0 RTM8940 NA (Management Controller Locator Record)
1
RTM:Module
HS
F0h (PICMG Hot Swap)
Event Type: 6Fh (Sensor-specific discrete)
* N
2
RTM:Temp
Board
01h (Temperature)
Event Type: 01h (Threshold)
* X
3
RTM:Temp
Outlet
01h (Temperature)
Event Type: 01h (Threshold)
* X
4
RTM:Vcc
+3.3VSUS
02h (Voltage)
Event Type: 01h (Threshold)
- X
5
RTM:Vcc
+3.3V
02h (Voltage)
Event Type: 01h (Threshold)
- X
6 RTM:Vcc +5V
02h (Voltage)
Event Type: 01h (Threshold)
- X
7
RTM:Vcc
+1.8V
02h (Voltage)
Event Type: 01h (Threshold)
- X
8
RTM:Vcc
+1.0V
02h (Voltage)
Event Type: 01h (Threshold)
- X
9 RTM:Vcc +12V
02h (Voltage)
Event Type: 01h (Threshold)
- X
10
RTM:Power
State
08h (Power Supply)
Event Type: 6Fh (Sensor-specific discrete)
* N
11
RTM:Power
Good
08h (Power Supply)
Event Type: 6Fh (Sensor-specific discrete)
* N
12
RTM:Pwr
Good Ev
08h (Power Supply)
Event Type: 6Fh (Sensor-specific discrete)
* N
13
RTM:Health
Error
24h (Platform Alert)
Event Type: 03h (digital discrete)
* N
14
RTM:Ver
Change
2Bh (Version Change)
Event Type: 6Fh (Sensor-specific discrete)
* N
15
RTM:IPMBL
State
C3h (OEM IPMB-L Link State)
Event Type: 6Fh (Sensor-specific discrete)
* N
16
RTM:MMC
Reboot
24h (Platform Alert)
Event Type: 6Fh (Sensor-specific discrete)
* N
Zobrazit stránku 21