Strany 1 - » User Guide «

» User Guide « Micro Client 3 104/121/150/170 Micro Client 3W 156 User’s Guide (Version 1.0) 1055-8487 www.kontron.com

Strany 2 - www.kontron.com

4. General Safety Instructions for IT Equipment Micro Client 3 – User’s Guide (Version 1.0) 4. General Safety Instructions for IT Equipment Pl

Strany 3 - 1. Table of Contents

4. General Safety Instructions for IT Equipment Micro Client 3 – User’s Guide (Version 1.0)  The DC-input must fulfill SELV requirements of EN6

Strany 4

4. General Safety Instructions for IT Equipment Micro Client 3 – User’s Guide (Version 1.0) 4.1. Electrostatic Discharge (ESD) A sudden disc

Strany 5 - 1.1. Table of Figures

5. Electromagnetic Compatibility Micro Client 3 – User’s Guide (Version 1.0) 5. Electromagnetic Compatibility 5.1. Electromagnetic Compatibility

Strany 6 - 1.2. Tables

6. Scope of Delivery Micro Client 3 – User’s Guide (Version 1.0) 6. Scope of Delivery Micro Client 3 and Micro Client 3W system in the confi

Strany 7 - 2. Introduction

6. Scope of Delivery Micro Client 3 – User’s Guide (Version 1.0) 6.2. Type Label and Product Identification System Type Part Number Product Ide

Strany 8

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7. Product Description Before you begin using your MC 3 system, you should

Strany 9 - 3. Important Instructions

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) Fig. 1: Bottom view Fig. 2: Right view Fig. 3: Frontal view Fig. 4:

Strany 10

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) Fig. 7: Bottom view Fig. 8: Right view Fig. 9: Frontal view Fig.

Strany 11

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.1. Front Side View Fig. 13: Frontal view of the MC 3 104/121/150/170 syste

Strany 12 - 4.2. Hot Surface Warning

This page is intentionally left blank. www.kontron.com

Strany 13 - 5.3. EMC Compliance Canada

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.1.1. USB Interface Connector on the Front Side of the MC 3 104/121/150/17

Strany 14 - 6. Scope of Delivery

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.1.3. Calibrating the Touch Screen (resistive) Calibration serves two purpose

Strany 15

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) Fig. 16: Select “Tools” tab Fig. 17: Select “4 Points Calibration” F

Strany 16 - 7. Product Description

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.1.4. Touch Screen Care and Cleaning The front panel and the touch screen ar

Strany 17

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.2. Bottom View Fig. 19: Bottom view of the MC 3 104 Fig. 20:

Strany 18

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) In the MC3 121/150/170 and MC 3W 156 systems up to three different modules f

Strany 19 - 7.1. Front Side View

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.2.2. Power Button and Control Indicators Fig. 22: Controls of the MC 3 s

Strany 20

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.2.2.3. Storage Drive Activity LED The MC 3 /MC 3 W systems can be optionall

Strany 21

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.2.3. Interfaces (Rear, Bottom Side of the System) Fig. 25: Detail with i

Strany 22 - Fig. 16: Select “Tools” tab

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.3. Optional Interfaces The optional interfaces (Fig. 25, Fig. 26 pos. 7 and

Strany 23

1. Table of Contents Micro Client 3 – User’s Guide (Version 1.0) 1. Table of Contents 1. Table of Contents ...

Strany 24 - 7.2. Bottom View

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) Termination Resistor for RS422 and RS485 SW1 Settings DIP4 Deactivated OF

Strany 25

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.3.2. DIP-Switch Settings (SW1) for LPCtoCAN Adapter The DIP-switch is for se

Strany 26 - 7.2.2.2. Power LED

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.3.2.3. NVRAM-Operation Mode (SW1: 7-8) Switch Mode 8 7 OFF OFF disable

Strany 27

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.4. Top View Fig. 30: Top side of the system (shown as MC 3W 156, with CF

Strany 28

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.4.1. CompactFlash™ Slot and SD card Slot The system is equipped with a Co

Strany 29 - 7.3. Optional Interfaces

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.5. Left and Right Side View Fig. 32: Right side shown as MC 3W 156 system

Strany 30

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.6. Rear View Fig. 36: Rear side of the system (shown as a MC 3W 156

Strany 31

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) The MC 3 system can be installed with the optional VESA® 100 compliant adapt

Strany 32

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) Fig. 39: Rear and bottom view of the mounting plate VESA® 75/100 for MC 3W

Strany 33 - 7.4. Top View

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.7. Installed SBC Your MC 3/MC 3W system is equipped with the HMI Single Boa

Strany 34

1. Table of Contents Micro Client 3 – User’s Guide (Version 1.0) 7.10. Getting started ...

Strany 35

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.9. Accessing Internal Components This section contains important informat

Strany 36 - 7.6. Rear View

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 5. By use of an insulated thin tool (e. g. screwdriver or a stylus) set the

Strany 37 - 100 compliant for MC 3 104

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.10. Getting started The MC 3/MC 3W system is designed to be powered from

Strany 38 - 36 www.kontron.com

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.11. Operating System and Hardware Component Drivers Your MC 3/MC 3W system c

Strany 39 - 7.8. DC Power Connection

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) 7.12. MC 3/MC 3W System Mounting to a Subframe or Panel The system configur

Strany 40

7. Product Description Micro Client 3 – User’s Guide (Version 1.0) The mounting clamps with screws (supplied), allow the easy and fast mounting o

Strany 41

8. Maintenance and Prevention Micro Client 3 – User’s Guide (Version 1.0) 8. Maintenance and Prevention Kontron Europe systems require minimal

Strany 42 - 7.10. Getting started

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) 9. Technical Data Features for Micro Client 3 Micro Client 3W 104 121 150 170 1

Strany 43

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) Features for Micro Client 3 Micro Client 3W 104 121 150 170 156 Storage Medi

Strany 44

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) Features for Micro Client 3 Micro Client 3W 104 121 150 170 156 Optional Parts

Strany 45 - 104/156/170

1. Table of Contents Micro Client 3 – User’s Guide (Version 1.0) 1.1. Table of Figures Fig. 1: Bottom view ...

Strany 46

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) 9.1. Electrical Specifications 9.1.1. Electrical Specifications for MC 3 104/12

Strany 47 - 9. Technical Data

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) 9.3. Mechanical Specifications 9.3.1. Dimensions for MC 3 104/121/150/170 and MC 3W

Strany 48 - (3-Pin)

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) Fig. 46: Frontal view of the MC 3 121 system Fig. 47: Frontal view of the MC

Strany 49 -     

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) Fig. 48: Frontal view of the MC 3 170 system www.kontron.com 51

Strany 50 - Nom (~32W)

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) Fig. 49: Frontal view of the MC 3W 156 system 52 www.kontron.com

Strany 51

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) MC 3 104 – right side view MC 3 121 – right side view MC 3 121 - rear view MC

Strany 52

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) MC 3 170 – right side view MC 3 150 – right side view MC 3 170 - rear view

Strany 53

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) MC 3W 156 - rear view MC 3W 156 – right side view www.kontron.com 55

Strany 54

9. Technical Data Micro Client 3 – User’s Guide (Version 1.0) 9.4. CE Directives and Standards CE Directives Low Voltage Directive (Electrical

Strany 55 - – right side view

10. Standard Interfaces – Pin Assignments Micro Client 3 – User’s Guide (Version 1.0) 10. Standard Interfaces – Pin Assignments Low-active signal

Strany 56

1. Table of Contents Micro Client 3 – User’s Guide (Version 1.0) Fig. 36: Rear side of the system (shown as a MC 3W 156 system) ...

Strany 57

10. Standard Interfaces – Pin Assignments Micro Client 3 – User’s Guide (Version 1.0) 10.1.3. Serial Port (RS422/RS485) configured as RS422 (4

Strany 58

10. Standard Interfaces – Pin Assignments Micro Client 3 – User’s Guide (Version 1.0) 10.1.5. Serial Port (RS422/RS485) configured as RS485 (2-Wi

Strany 59

10. Standard Interfaces – Pin Assignments Micro Client 3 – User’s Guide (Version 1.0) 10.1.7. DP Connector (DisplayPort) Pin Signal Name 20-

Strany 60

11. Technical Support Micro Client 3 – User’s Guide (Version 1.0) 11. Technical Support For technical support, please contact our Technical Suppo

Strany 61

2. Introduction Micro Client 3 – User’s Guide (Version 1.0) 2. Introduction Kontron Europe would like to point out that the information contained

Strany 62

2. Introduction Micro Client 3 – User’s Guide (Version 1.0) 2.1. Symbols used in this User’s Guide Symbol Meaning This symbol indicates the

Strany 63 - 11. Technical Support

3. Important Instructions Micro Client 3 – User’s Guide (Version 1.0) 3. Important Instructions This chapter contains instructions which must be

Komentáře k této Příručce