Kontron CG2100 Carrier Grade Server Uživatelský manuál Strana 54

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 110
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 53
53
To install the SD flash module, you must first power-down the system and remove the
chassis front cover and front bezel.
1. Remove the front chassis cover. For instructions, see “Removing the Front Cover” in
Section 3.2.
2. Remove the front panel bezel from the chassis to access the optical device slot.
3. Unfasten the black protective cover over the front panel board.
4. Remove the filler panel from the front on the server chassis. (Figure 47, “A”) and
save the two screws for use with the SD flash module bracket.
Slide the filler panel out of the chassis through the front. (“B”)
Figure 47. Removing the SD Flash Module Filler Panel
5. Line up the SD flash module with the stand-offs on the bracket and secure the
module with the two hex screws in the package. (Figure 48, “A” and “B”)
Figure 48. Installing the SD Flash Module in the Bracket
Zobrazit stránku 53