December 2009 Product Guide, rev. 1.4
69
Server Component Replacements—NSW1U Network Server
4. Disconnect the following cables on the EFP board:
All fan power cables (three CPU/memory fans and PCI fan)
•Flex cable
Optical device power cable
SATA hard drive connectors
SMART Embedded USB Solid-State Drive cable, if installed
4xGbE LAN card cables, if installed
Power interconnect to PDB
5. Remove the screws (Figure 53, “A”).
6. Gently work the EFP board backward (“B”), toward the rear of the chassis to disengage the light
pipe assembly from behind the front control panel bezel.
7. Pull the front panel I/O board up over the placement pegs (“C”) and lift it from the chassis.
Figure 53. Removing the EFP Board
A
B
C
C
AF000896