101
5.2.2 Replacing the CPU Fans
1. Lower the CPU fans into the chassis. (“A”)
2. Set the fans in the fan alignment bracket so that the shaft of the grommet (not the
head of the grommet) rests within the notch in the bracket. (“B”)
3. Make certain that the grommet heads on the other side of the fans rest near (or
against) the SAS Front Panel Board. (“C”)
4. Plug the fan power cables back into the SAS Front Panel board connectors. (“D”)
5. If this is the last task you are performing, replace the processor air duct and the
top cover of the chassis. Reconnect all the external devices and plug in the power
cord(s).
Figure 87. Replacing the CPU Fans