3. Connect the five power supply harness connectors on the server board and the SFP
board.
4. Replace the drive bay assembly.
5. Replace the PCI riser card assembly.
6. Replace the PCI fan assembly and the CPU fan assembly and processor air duct.
7. If this is the last task you are performing, replace the top cover of the chassis.
Reconnect all the external devices and plug in the power cord(s).
For information about mounting the server in a rack, see Section 3.5, “Installing
the Server into a Rack” on page 48.
5.6 Replacing the Server Board
The IP Network Server NSC2U uses the Intel
®
Server Board T5000PAL. To replace the
server board, the following components must be removed:
Processor air duct
CPU fan assembly
PCI riser assembly and add-in cards
Any I/O expansion module or RMM module
Cables connected to the board and the bridge board
The HDD drive bay assembly
In addition, you may want to remove the following components on the board to re-use
them on the replacement board if it isn’t already populated:
•Heat sink(s)
Processor(s)
Figure 102. Installing the PDB
TS000569
A
B